ТОВ ТМ «ПРОМ-ОКЕАН»
magnifying-desktop
    +380 (67) 638 48 75

    prom-ocean@ukr.net

    Language : Language
    • Russian
    • English
    • Українська
    menu

    SHOP BY CATEGORIES

    • About company
    • Investors
      • Bonds
      • Credit rating
      • Key figures
      • Presentations
    • Technical documentation
      • Passports of pumps
      • Instruction
    • Pumps
      • Axial
      • Centrifugal
      • Chemical
      • coal pumps
      • Condensate
      • Console
      • Construction pumps
      • Dispensers
      • Downhole
      • Drilling
      • food
      • Gear pumps
      • Ground, sand, slurry
      • Horizontal double-sided entry
      • hydraulic
      • impeller
      • Industrial oil pumps
      • lamellar
      • Manure pumps
      • Network
      • New
      • NKU type
      • Nutrients
      • Oil
      • Piston
      • Pumping stations
      • screw
      • Sectional
      • sewer pumps
      • Submersible
      • vacuum
      • vertical
      • Vortex
      • Waste-dynamic
      • Waste-mass
      • Petrol
      • bituminous
    • Enterprise need
    • Our services
    • Electric motors
      • Electric motors MPE, MPVE
      • General industrial
      • Romanian electric motors
      • Traction motors
      • explosion-proof
      • Crane
      • Lift
      • Marine
      • Direct current
      • Roller table (special)
      • High voltage
      • WEG electric motors
      • Technical documentation
    • Home
    • Contact
    • About Us
    • +38 (048) 775 15 21
    • +38 (044) 232 39 65
    • prom-ocean@ukr.net
    View More
    Menu
    Language : Language
    • Russian
    • English
    • Українська
    Account
    • Register
    • Login
    • Wish List (0)

    Categories

    Categories
    • About company
    • Engineering and Integration
    • Investors
    • Our partners
    • Technical documentation
    • Pumps
      •    - Axial
      •    - Centrifugal
      •    - Chemical
      •    - coal pumps
      •    - Condensate
      •    - Console
      •    - Construction pumps
      •    - Dispensers
      •    - Downhole
      •    - Drilling
      •    - food
      •    - Gear pumps
      •    - Ground, sand, slurry
      •    - Horizontal double-sided entry
      •    - hydraulic
      •    - impeller
      •    - Industrial oil pumps
      •    - lamellar
      •    - Manure pumps
      •    - Network
      •    - New
      •    - NKU type
      •    - Nutrients
      •    - Oil
      •    - Piston
      •    - Pumping stations
      •    - screw
      •    - Sectional
      •    - sewer pumps
      •    - Submersible
      •    - vacuum
      •    - vertical
      •    - Vortex
      •    - Waste-dynamic
      •    - Waste-mass
      •    - Petrol
      •    - bituminous
    • Enterprise need
    • Our services
    • Electric motors
    Pump OPVU 2500 - 4.2
    Pump OPVU 2500 - 4.2
    To learn more

    Divac T type pumps

    • Pumps
    • vacuum
    • Divac T type pumps

    Divac T type pumps

    Divac T type pumps
    Description

    Membrane pumps of the Divac T series include forvacuum pumps that are used to be used. In areas requiring low pressure and high level of vacuum that does not contain impurities of hydrocarbons.

    Fields of application :
    - Mass spectrometry
    - Medical equipment
    - for Laboratory Research , as well as turning on aggressive media s

    Divac 0.8 T


    Divac 0.8 lt

    Name of the parameter

    Meaning

    1 entrance flange

    DN 16 ISO-KF, G 1/8 ’’ inside

    2 output flanet

    Exhaust muffler, g 1/8 ’’ intern.

    3 speed of action, m 3 /h

    0.6

    4 maximum residual pressure, MBAR (mm Hg)

    ≤ 3 (≤ 2.25)

    5 maximum exhaust pressure, mbar

    2000

    6 noise level, dB

    49

    7 ELECTION EL/DOWN. From a network of single -phase alternating current with a frequency of 50/60 Hz, voltage, in

    from 198 to 264

    8 power of the electric motor, W

    50

    9 angular velocity at a frequency of 50 Hz, rpm

    1500

    10 angular velocity at a frequency of 60 Hz, rpm

    1800

    10 Elector protection level

    IP 44

    11 Permissible gas temperature at the input, o s

    +5 to +40

    12 Permissible ambient temperature, o s

    +5 to +40

    13 mass, kg

    5.9


    "> "> Divac 1.4 HV3

    Name of the parameter

    Meaning

    1 entrance flange

    DN 16 ISO-KF, G 1/8 ’’ inside

    2 output flanet

    Exhaust muffler, g 1/8 ’’ intern.

    3 speed of action, m 3 /h

    0.6

    4 maximum residual pressure, MBAR (mm Hg)

    ≤ 0.5 (≤ 0.38)

    5 maximum exhaust pressure, mbar

    2000

    6 noise level, dB

    53

    7 ELECTION EL/DOWN. From a network of single -phase alternating current with a frequency of 50/60 Hz, voltage, in

    230

    8 power of the electric motor, W

    80

    9 angular velocity at a frequency of 50 Hz, rpm

    1500

    10 angular velocity at a frequency of 60 Hz, rpm

    1800

    10 Elector protection level

    IP 44

    11 Permissible gas temperature at the input, o s

    +5 to +40

    12 Permissible ambient temperature, o s

    +5 to +40

    13 mass, kg

    7.5


    "> "> Divac 3.8 HV3

    Name of the parameter

    Meaning

    1 entrance flange

    G 1/8 ’’ inside

    2 output flanet

    G 1/8’’ltr.

    3 speed of action, m 3 /h

    1.3

    4 limit full pressure, MBAR (mm Hg)

    ≤ 1.5 (≤ 1.13)

    5 maximum exhaust pressure, mbar

    1500

    6 noise level, dB

    48

    7 ELECTION EL/DOWN. From a network of single -phase alternating current with a frequency of 50/60 Hz, voltage, in

    90-230

    8 power of the electric motor, W

    120

    9 angular velocity at a frequency of 50 Hz, rpm

    1500

    10 angular velocity at a frequency of 60 Hz, rpm

    1800

    10 Elector protection level

    IP 20

    11 Permissible gas temperature at the input, o s

    +5 to +40

    12 Permissible ambient temperature, o s

    +5 to +40

    13 mass, kg

    10.5


    "> "> Divac 4.8 VT

    Name of the parameter

    Meaning

    1 entrance flange

    G 1/4 ’’ inside

    2 output flanet

    G 1/4 ’’ inside

    3 speed of action at a frequency of 50 Hz, m 3 /h

    3.4

    4 speed of action at a frequency of 60 Hz, m 3 /h

    3.8

    4 maximum residual pressure, MBAR (mm Hg)

    ≤ 1.0 (≤ 0.75)

    5 maximum exhaust pressure, mbar

    1500

    6 noise level, dB

    54

    7 ELECTION EL/DOWN. From a network of single -phase alternating current with a frequency of 50/60 Hz, voltage, in

    from 90 to 230

    8 power of the electric motor, W

    120

    9 angular velocity at a frequency of 50 Hz, rpm

    1500

    10 angular velocity at a frequency of 60 Hz, rpm

    1800

    10 Elector protection level

    IP 20

    11 Permissible gas temperature at the input, o s

    +5 to +40

    12 Permissible ambient temperature, o s

    +5 to +40

    13 mass, kg

    18.9

    Reviews (0)

    Write a review

    Note: HTML is not translated!
       
    Bad           Good

    Divac T type pumps

    0 reviews / Write a review

    • Product Code: Насосы типа DIVAC T
    • Availability: In Stock

    Request for

    Contact Us
    Contact Us
    office 16, 38 Svyatytelya Vasylya Velykoho str., KRIVYI RIH, Dnipro region, 50071, Ukraine
    +380 (67) 638 48 75
    prom-ocean@ukr.net
    Information
    Information
    • Commercial offers
    • Companies with which we cooperate
    • Dealership
    • Documentation
    • Letters of recommendation
    • Manufacturers
    • Our team
    • Payment and delivery
    • Product Catalog
    • Stock
    • Video gallery
    • About company
    • Privacy Policy
    • Terms & Conditions
    NESWLETTER

    Sing up for latest offers and promotions

    Submit

    Social
    Paymenticon
    +38(099)645-38-77
    +38(099)645-38-77
    Telegram
    Viber
    Whatsapp
    Mail
    • +38(099)645-38-77+38(099)645-38-77
    • +38(099)645-38-77+38(099)645-38-77
    • TelegramTelegram
    • ViberViber
    • WhatsappWhatsapp
    • MailMail

    Name of the parameter

    Meaning

    1 entrance flange

    DN 16 ISO-KF,

    G 3/8 ’’ inside

    2 output flanet

    Exhaust muffler, g 3/8 ’’ intern.

    3 speed of action, m 3 /h

    4.7

    4 maximum residual pressure, MBAR (mm Hg)

    ≤ 2.0 (≤ 1.5)

    5 maximum exhaust pressure, mbar

    2000

    6 noise level, dB

    55

    7 ELECTION EL/DOWN. From a network of single -phase alternating current with a frequency of 50 Hz, voltage, in

    230

    8 power of the electric motor, W

    350

    9 angular velocity at a frequency of 50 Hz, rpm

    1500

    10 angular velocity at a frequency of 60 Hz, rpm

    1800

    11 Elector protection level

    IP 54

    12 The permissible temperature of the gas at the entrance, o s

    +5 to +40

    13 Permissible ambient temperature, o s

    +5 to +40

    14 mass, kg

    18.0