Axual-piston-piston controlled types of NGM 56/32 with a power regulator are used in volumetric hydraulic drives of machines and assemblies in the regulated pump mode.
The pump is designed to convert the mechanical energy supplied to the drive shaft, into the energy fluid flow.
The pumps are made with a slotted or key -wide output ends of the shaft. The direction of rotation is the left.
Recommended oil grades: VMGZ TU38.101479, MGE-46V TU 38.001347, TNK hydraulics HLP 32, 46, 68 TU38.301-41-180-01, LUKOIL geyser ST 22, 32, 46 TS 0253-011-7934251- 2008.
Name of the parameter | the value td> TR> |
pump td> TR> | |
working volume td> | TR> |
nominal (vnom), cm 3 | 56 td> TR> |
minimum (vmin), cm 3 | 20 td> TR> |
Rotation frequency at vnom, with -1 (rpm) | TR> |
nominal td> | 25 (1500) | TR>
minimum td> | 3.3 (200) | TR>
maximum td> | 33.3 (2000) | TR>
feed, l/min | TR> |
nominal, no less | 80 -2 | TR>
Pressure on the output, MPa, (KGS/cm 2 ) | TR> |
nominal td> | 32 (320) | TR>
maximum td> | 40 (400) | TR>
Pressure at the input, MPa, (KGS/cm 2 ) | TR> |
maximum td> | 0.2 (2) | TR>
minimum (absolute) for open schemes | 0.08 (8) | TR>
Drainage pressure, MPa, (KGS/cm 2 ) | TR> |
maximum td> | 0.2 (2) | TR>
the power supported by the regulator, kW | 15 ± 39 | TR>
nominal power consumption, kW, no less | 48,8 +1.2 | TR>
efficiency, % not less: | TR> |
full td> | 90 td> TR> |
feed coefficient, % | 95 td> TR> |
mass (without working fluid), kg | 27 td> TR> |