Academy of Electroly -based piston types are designed for pumping water (except for drinking and marine) and neutral liquids
with kinematic viscosity from 0.008x10 -4 Sup> up to 8x10 -4 SUP> M 2 /s and temperature from 258 K to 353 K (from minus 15 to plus 80 ° C). Units can be delivered for pumping fluid with a temperature of up to 378 K (105 ° C), which is specified during order. The maximum volumetric concentration of solid non -abrasive particles in the pumped medium is 0.2%, the maximum particle size is 0.2 mm.
Acts are used in low -power boiler houses.
The aggregate includes: a pumping bunk quadruple and an electric motor. The pump consists of two parts: drive and hydraulic. The drive part contains belt and gear gears. The hydraulic part contains two hydraulic cylinders and two valve boxes with suction and injection ball valves. The unit is mounted on the drive of the drive part.
Size |
Serve |
Pressure on the output of the pump, MPa KGS/cm 2 Sup> |
The number of double passages of the plunger in min. |
Permissible vacuumic absorption height, No less |
engine type; Power, kW |
overall dimensions (LXBXX), mm |
mass, kg |
TR>
An 1/16 |
1 ± 10% |
1.6 (16) |
110 |
6 |
AIR80V6U3; 1000; 1.1 |
710x350x450 |
110 |
TR>
An 2/16 |
2 ± 10% |
1.6 (16) |
165 |
6 |
AIR80V4U3; 1500; 1.5 |
710x350x450 |
110 |
TR>