Technical characteristics of thermal pumping pumps “brine” - “water” with a thermal capacity from 5 to 44 kW
type of thermal pump |
tn1 r/in 05 |
tn1 r/in 07 |
tn1 r/in 10 |
tn1 r/in 13 |
tn1 r/in 16 |
tn1 r/in 21 |
tn1 r/in 25 |
tn1 r/in 36 |
tn1 r/in 44 |
TR>
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Thermal power (B0/W35) 1 SUP>, kW | 5.8 | 6.9 | 11,1 | 13.6 | 16.2 | 21.2 | 29.6 | 36.2 | 44.0 | TR>||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electric power consumption (B0/W35) 1 SUP>, kW | 1.4 | 1.7 | 2.4 | 2.9 | 3.5 | 4,8 | 6.5 | 8.0 | 9.7 | TR>||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SOR - transformation coefficient (B0/W35) 1 SUP>, TD>
4.1 |
4.1 |
4.6 |
4.6 |
4.6 |
4,4 |
4.5 |
4.5 |
4.5 |
TR>
Thermal power (B0/W55), kW |
5.1 |
6.3 |
10.4 |
12.5 |
14.9 |
18.6 |
26.7 |
31.9 |
39.8 |
TR>
Electric power consumption (B0/W55) 1 SUP>, kW |
2.1 |
2.5 |
3.8 |
4.5 |
5.4 |
6.7 |
9.4 |
11,1 |
14.3 |
TR>
Nominal current consumed, and |
2.8 |
3.3 |
4,8 |
5.9 |
7.1 |
11.4 |
13.2 |
15.3 |
19,1 |
TR>
Working current max, and |
5.0 |
5.0 |
8.2 |
10.1 |
11.8 |
16.0 |
21.0 |
25.0 |
32.0 |
TR>
The starting current of the engine with a smooth start, and |
13.0 |
16.0 |
25.8 |
32.0 |
37.0 |
49.5 |
63.5 |
83.5 |
99.0 |
TR>
The nominal consumption of the loop in the circuit of the heat energy source, m 3 Sup>/h |
1.380 |
1.710 |
2.760 |
3.410 |
4,050 |
5,140 |
7.350 |
8,960 |
10,880 |
TR>
Nominal water consumption in the heating circuit, m 3 Sup>/h |
0.99 |
1.190 |
1.9 |
2.330 |
2.780 |
3.570 |
4,690 |
6.150 |
7,480 |
TR>
Hydraulic losses of heat exchanger - source of thermal energy, kPa |
10.5 |
10.0 |
11.5 |
13.0 |
14.0 |
16.0 |
15.0 |
16.5 |
15.0 |
TR>
Hydraulic losses of the heat exchanger of the heating system, KPA |
5.0 |
4.0 |
5.0 |
6.5 |
7.0 |
12.0 |
10.0 |
12.0 |
11.0 |
TR>
Dimensional dimensions, mm |
700x750x900 |
700x950x900 |
700x1000x1100 |
TR>
|
type of thermal pump |
tn1 r/in 06 230V TD> |
tn1 r/in 07 230V TD> |
tn1 r/in 08 230V TD> |
tn1 r/in 10 230V TD> |
tn1 r/in 11 230V TD> TR> | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Thermal power (B0/W35) 1 SUP>, kW | 5.9 | 7.0 | 8.2 | 10.1 | 11,2 | TR>|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electric power consumption (B0/W35) 1 SUP>, kW | 1.5 | 1.7 | 2.0 | 2.5 | 2.8 | TR>|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SOR - transformation coefficient (B0/W35) 1 SUP>, TD>
4.1 |
4.1 |
4.1 |
4.1 |
4.0 |
TR>
Thermal power (B0/W55), kW |
5.6 |
6.6 |
7.8 |
9.6 |
10.3 |
TR>
Electric power consumption (B0/W55) 1 SUP>, kW |
2.1 |
2.5 |
3.0 |
3.6 |
4,2 |
TR>
Nominal current consumed, and |
7.2 |
8.5 |
10.0 |
12.8 |
14.5 |
TR>
Working current max, and |
14.8 |
17.3 |
23,1 |
23.5 |
30.0 |
TR>
The starting current of the engine with a smooth start, and |
30.0 |
30.0 |
30.0 |
30.0 |
40.0 |
TR>
The nominal consumption of the loop in the circuit of the heat energy source, m 3 Sup>/h |
1.410 |
1.690 |
1.990 |
2.420 |
2.670 |
TR>
Nominal water consumption in the heating circuit, m 3 Sup>/h |
0.510 |
0.600 |
0.710 |
0.870 |
0.970 |
TR>
Hydraulic losses of heat exchanger - source of thermal energy, kPa |
12 |
16 |
13 |
18 |
15 |
TR>
Hydraulic losses of the heat exchanger of the heating system, KPA |
2 |
3 |
3 |
3 |
4 |
TR>
Dimensional dimensions, mm |
700x750x900 |
TR>
|
type of thermal pump |
TN2 R/B 21 |
TN2 R/B 25 |
TN2 R/B 30 TD> |
TN2 R/in 33 |
TN2 R/in 37 |
TN2 R/in 46 |
TN2 R/in 50 |
TN2 R/in 65 |
TN2 R/in 78 |
TR>
|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Thermal power (B0/W35) 1 SUP>, kW | 21.2 (10.6) | 25.6 (12.8) | 30 (15.0) | 33.4 (16.7) | 37.4 (18.7) | 46 (23) | 53.2 (26.2) | 65.8 (32.9) | 79.6 (39.8) | TR>|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electric power consumption (B0/W35) 1 SUP>, kW | 4.8 (2.4) | 5.8 (2.9) | 6.8 (3.4) | 7.4 (3.7) | 8.6 (4,3) | 10.6 (5.3) | 12 (6) TD> | 15 (7.5) | 18.2 (9.1) | TR>|||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
SOR - transformation coefficient (B0/W35) 1 SUP> TD>
4,4 |
4,4 |
4,4 |
4,4 |
4,4 |
4,4 |
4,4 |
4,4 |
4,4 |
TR>
Thermal power (B0/W55), kW |
20.2 (10.1) |
24.2 (12.1) |
28.0 (14.0) TD>
|
31.8 (15.9) |
35.8 (17.9) |
44.0 (22.0) |
50.8 (25.4) |
62.6 (31.3) |
76.4 (38.2) |
TR>
Electric power consumption (B0/W55) 1 SUP>, kW |
6.8 (3.4) |
8.2 (4.1) |
9.6 (4.8) |
10.8 (5.4) |
12.4 (6.2) |
14.8 (7.4) |
17 (8.5) |
21 (10.5) |
25.6 (12.8) |
TR>
Nominal current consumed, and |
10.6 (5.3) |
13.2 (6.6) |
13 (6.5) |
16.8 (8.4) |
21 (10.5) |
25.2 (12.6) |
25.6 (12.8) |
28.6 (14.8) |
35.4 (17.7) |
TR>
Working current max, and |
20 (10) TD>
|
22 (11) |
26 (13) TD>
|
30 (15) TD>
|
34 (17) TD>
|
40 (20) TD>
|
44 (22) |
54 (27) TD>
|
64 (32) TD>
TR>
|
The starting current of the engine with a smooth start, and |
35 (25) |
44 (33) TD>
|
48 (35) TD>
|
65 (50) |
67 (50) TD>
|
82 (62) TD>
|
86 (64) TD>
|
111 (84) TD>
|
131 (99) TD>
TR>
|
The nominal consumption of the loop in the circuit of the heat energy source, m 3 Sup>/h |
5,270 |
6,030 |
7.060 |
8.350 |
8,770 |
10.780 |
12.540 |
15,470 |
18,690 |
TR>
Nominal water consumption in the heating circuit, m 3 Sup>/h |
1.830 |
2.210 |
2.590 |
2.880 |
3.230 |
3.980 |
4,600 |
5,690 |
6,880 |
TR>
Hydraulic losses of heat exchanger - source of thermal energy, kPa |
14.5 |
14 |
14 |
16.4 |
21 |
23 |
24 |
25 |
26 |
TR>
Hydraulic losses of the heat exchanger of the heating system, KPA |
3.1 |
4.0 |
4.0 |
3.4 |
5.0 |
6.0 |
6.0 |
6.0 |
6.0 |
TR>
Dimensional dimensions, mm |
700x950x900 |
700x1000x1100 |
TR>
|
Motor | |
Power kW | 30 |
Frequency rpm | 1000 |