Pumping SNN stations are designed to power the working fluid of hydraulic systems of mechanized vehicles of treatment complexes in mines and coal mines, including hazardous gas and dust. The area of application of the station is mining with an angle of inclination of not more than 5 ° C. The environment is the slabs of mines and mines with a temperature from plus 5 to plus 35 ° C and relative humidity up to 98 % at a temperature of up to plus 25 ° C. Category of mines and coal mines for gas and dust - any.
The working fluid is a water-oil emulsion or other emulsion, allowed for use in hydraulic systems of mining equipment, with an additive concentration of 1.5% to 5%. The class of purity of working fluid is not lower than 17 according to GOST 17216 with the nominal subtlety of filtering 80 microns.
Type of climatic performance U5 according to GOST 15150.
Ensuring explosion protection
">
The delivery set includes: h4>
-
hydraulic tank (with a filter of the drain line and a node of the pneumohydractulator),
-
pump unit - 2pcs.,
-
The filter of the cluster line (with reverse washing),
-
Magistral pressure navigan Du25,
-
Magistral drainage hose hopp from DU32;
-
set of spare parts,
-
A set of tools and accessories,
-
Operational documentation.
Description h2>
"> Name of the parameter |
Value SPAN> TD>
TR>
|
SNN 150/30 SPAN> |
SNN 200/32 SPAN> |
SNN 100/32 SPAN> |
TR>
">
Nominal feed, l/min |
160 |
200 |
110 |
TR>
Output pressure, MPa: |
-The maximum - minimum
32 |
12
|
32 20
|
TR>
32 12 ">
The drop in high pressure in the highway |
during the unloading of the pump, %, no more
20 |
20 |
20 |
TR>
Nominal power of the pump electric motor, kW |
90 |
110 |
55 |
TR>
">
The power circuit voltage, in |
1140/660 TD>
TR>
|
Specific electricity consumption for the supply of 1 liter of working fluid, W Min/L, no more than |
563 |
560 |
500 |
TR>
">
Nominal capacity of the tank, l |
2000 |
TR>
Supply valve settings pressure, MPa |
38 |
TR>
">
Lubrication pump pressure, MPa |
from 0.25 to 1.2 |
TR>
Oil temperature in the pump crankcase, ° C |
from +5 to +80 |
TR>
">
The temperature of the working fluid, ° C |
from +5 to +50 |
TR>
Pneumon -accumulator capacity, l |
32 |
TR>
">
Dimensional dimensions, no more, mm |
10700x1500x1040 |
11370x1730x1040 |
1000x1000x1040 |
TR>
Mass, no more, kg |
5800 |
6500 |
4800 |
TR>
|