"> "> ND is a new generation of high -bus -caring diffusion steam oil pumps h1>
Pumps Vacuum diffusion steam-oil ND with air and gas are designed for pumping out air, gases , vapors and steam-gas mixtures that do not contain drip moisture and mechanical contaminants and are not aggressive to the materials and working fluid of the pump.
Pumps are designed to work in an explosion-proof room.
differ from the pumps of the NVDM series of the low vacuum, the workers' range of workers pressures and significantly improved exhaust pressure.
The parametric series of ND pumps (conditional passage diameter) 250, 250 400, 500, 630, 800 and 1000 mm. ND pumps have a cylindrical zygated case, inside which there are a steamboard with a nozzle system, a working fluid heating system and an oil refiner. The optimally calculated design of ND pumps provides high specific characteristics.
"> "> ND-250 h1>
Name of the parameter |
Meaning |
TR>
1 speed of action by air at a pressure, l/s
7.5 · 10 -3 Sup> mm Hg.
7.5 · 10 -4 Sup> mm Hg.
7.5 · 10 -5 Sup> mm Hg.
|
225 1500 2700 |
TR>
2 The highest exhaust pressure, mm Hg. |
0.45 |
TR>
|
2.25 ∙ 10 -7 |
TR>
|
2.4 |
TR>
5 the number of heaters, pcs. |
2 |
TR>
6 power voltage, in |
220 ± 10% |
TR>
7 Output time, min |
25 |
TR>
max min |
1.8 1.3 |
TR>
9 of the consumption of cooling water, l/h: on the pump on the oil reflector |
160 20 |
TR>
10 overall dimensions, mm, no more than*: height length width |
560 (580) 470 (475) 440 (445) |
TR>
11 mass, kg, no more than ** |
28 (33) |
TR>
P R and M E H and E: * without plugs and details of their fastening; ** without plugs, details of their fastening and working fluid. () - values for ND -250r. |
TR>
Name of the parameter |
Meaning |
TR>
1 speed of action by air at a pressure, l/s
7.5 · 10 -3 Sup> mm Hg.
7.5 · 10 -4 Sup> mm Hg.
7.5 · 10 -5 Sup> mm Hg.
|
600 4000 7200 |
TR>
2 The highest exhaust pressure, mm Hg. |
0.45 |
TR>
from 10 0 Sup> C to 45 0 Sup> s from 25 0 Sup> C to 45 0 Sup> s |
2.25 ∙ 10 -7 2.25 ∙ 10 -6 |
TR>
|
4,8 |
TR>
5 the number of heaters, pcs. |
6 |
TR>
6 power voltage, in |
220/380 ± 10% |
TR>
7 Output time, min |
30 |
TR>
max min |
5.0 3.3 |
TR>
9 of the consumption of cooling water, l/h: on the pump on the oil reflector |
250 40 |
TR>
10 overall dimensions, mm, no more than*: height length width |
785 (800) 630 530 |
TR>
11 mass, kg, no more than ** |
58 (80) |
TR>
Name of the parameter and size h1> |
Meaning h1> |
TR>
1 speed of action by air at a pressure, l/s
7.5 · 10 -3 Sup> mm Hg.
7.5 · 10 -4 Sup> mm Hg.
7.5 · 10 -5 Sup> mm Hg.
|
900 6000 10800 |
TR>
2 The highest exhaust pressure, mm Hg. |
0.45 |
TR>
|
2.25 ∙ 10 -7 |
TR>
|
7.2 |
TR>
5 the number of heaters, pcs. |
9 |
TR>
6 power voltage, in |
220/380 ± 10% |
TR>
7 Output time, min |
30 |
TR>
max min |
5.5 4,0 |
TR>
9 of the consumption of cooling water (450 l/h per part of the case), l/h: on the pump on the oil reflector |
500 50 |
TR>
10 overall dimensions, mm, no more than*: height length width |
940 818 630 |
TR>
11 mass, kg, no more than ** |
92 |
TR>
Name of the parameter |
Meaning |
TR>
1 speed of action by air at a pressure, l/s
7.5 · 10 -3 Sup> mm Hg.
7.5 · 10 -4 Sup> mm Hg.
7.5 · 10 -5 Sup> mm Hg.
|
1500 10000 18000 |
TR>
2 The highest exhaust pressure, mm Hg. |
0.45 |
TR>
|
2.25 ∙ 10 -7 |
TR>
|
12 |
TR>
5 the number of heaters, pcs. |
12 |
TR>
6 power voltage, in |
220/380 ± 10% |
TR>
7 Output time, min |
30 |
TR>
max min |
9 6 |
TR>
9 of the consumption of cooling water, l/h: on the pump on the oil reflector |
600 80 |
TR>
10 overall dimensions, mm, no more than*: height length width |
1130 1045 820 |
TR>
11 mass, kg, no more than ** |
180 |
TR>
Name of the parameter |
Meaning |
TR>
1 speed of action by air at a pressure, l/s
7.5 · 10 -3 Sup> mm Hg.
7.5 · 10 -4 Sup> mm Hg.
7.5 · 10 -5 Sup> mm Hg.
|
2250 15000 27000 |
TR>
2 The highest exhaust pressure, mm Hg. |
0.45 |
TR>
from 10 0 Sup> C to 45 0 Sup> s from 25 0 Sup> C to 45 0 Sup> s |
2.25 ∙ 10 -7 2.25 ∙ 10 -6 |
TR>
|
18 |
TR>
5 the number of heaters, pcs. |
18 |
TR>
6 power voltage, in |
220/380 ± 10% |
TR>
7 Output time, min |
40 |
TR>
max min |
15 10 |
TR>
9 of the consumption of cooling water (450 l/h per part of the case), l/h: on the pump on the oil reflector |
900 120 |
TR>
10 overall dimensions, mm, no more than*: height length width |
1450 1040 1000 |
TR>
11 mass, kg, no more than ** |
300 |
TR>
Name of the parameter |
Meaning |
TR>
1 speed of action by air at a pressure, l/s
7.5 · 10 -3 Sup> mm Hg.
7.5 · 10 -4 Sup> mm Hg.
7.5 · 10 -5 Sup> mm Hg.
|
3500 23000 45000 |
TR>
2 The highest exhaust pressure, mm Hg. |
0.45 |
TR>
from 10 0 Sup> C to 45 0 Sup> s from 25 0 Sup> C to 45 0 Sup> s |
2.25 ∙ 10 -7 2.25 ∙ 10 -6 |
TR>
|
24 |
TR>
5 the number of heaters, pcs. |
24 |
TR>
6 power voltage, in |
220/380 ± 10% |
TR>
7 Output time, min |
45 |
TR>
max min |
23 16 |
TR>
9 of the consumption of cooling water (450 l/h per part of the case), l/h: on the pump on the oil reflector |
1500 150 |
TR>
10 overall dimensions, mm, no more than*: height length
|