The industries:
- Chemical and petrochemical industry,
- Oil processing industry,
- Energy,
- fuel storage.
Passed liquids:
- Light oil products (gasoline, diesel fuel, kerosene, etc.),
- Technical alcohols,
- Passing of organic synthesis, in particular pyrolysis resin,
- containing solid inclusions in an amount of not more than 0.01% by weight, with particles of not more than 0.2 mm and kinematic viscosity of liquids - not more than 20 S -SCT. Density 0.71 ÷ 1.0 g/cm 3 SUP>, temperature from-50 O SUP> C to +45 O SUP> p.
Type of structure:
- The system of hydraulic unloading of the axial force reduces the axial load on the electric motor bearings, significantly increasing the pump resource.
- The running part of the KMN pumps is made of corrosion -resistant aluminum alloy,
- It is equipped with an explosion -proof electric motor,
- Type of climatic performance U2,
- Athlet seal - single with additional cuffs,
- It is possible to make pumps according to the individual requirements of the customer (feed, pressure, climatic execution, seats for sensors, frame, etc.).
- Numeria of the pump is a three -phase alternating current, with a voltage of 380 centuries.
Technical characteristics: < < Br Style = "Box-Sizing: Border-Box; Color: RGB (68, 68, 68); Font-Family: Tenor Sans, Tahoma; Font-Size: 15.04PX;" />
Pump brand |
Nomin. Submission, m3/h |
Nomin. Napro, M |
Power engine, kW. |
Dimensions Without containers, mm |
Mass Without containers, kg |
TR>
KMN 80-65-155 | 20-51 | 23-32 | 5.5 | 617x365x470 | 77 | TR>
KMN 80-65-175 | 40-78 | 26-33 | 11 | 750x370x540 | 120 | TR>
*Nominal feed (m3/h)/pressure (m.) | KMN 80-65-155 (5.5 kW) TD> | KMN 80-65-175 (11 kW) TD> TR> |
Values | TR>||
1 nominal feed (by water): m3/h; l/s; m3/s. |
30 8.3 0.008 |
50 14 0.013 |
TR>
2 nominal feed, m3/h, when pumping: -diesel fuel, density 850 kg/m3 -benzin, density 760 kg/m3 |
36 39 |
60 65 |
TR>
3 Nominal pressure, m | 30 ± 10% | 30 ± 10% | TR>
4 operating range of feeds, m3/h (by water) | 20 ÷ 40 | 40 ÷ 60 | TR>
5 operating range of feeds, m3/h (according to diesel fuel, density 850 kg/m3) TD> | 24 ÷ 45 | 48 ÷ 72 | TR>
6 operating range of feeds, m3/h (according to gasoline, density 760 kg/m3) TD> | 26 ÷ 51 | 52 ÷ 78 | TR>
7 pressure in the working range, m | 32 ÷ 23 | 33 ÷ 26 | TR>