Pumps are designed to pump water into oil reservoirs in order to artificially maintain intraise pressure in the extraction of oil, gas and condensate, as well as for creating high pressure in the processes of oil, gas and gas condensation processes, in the technological processes of oil and gas chemistry .
Pumps such as the Central Military District - horizontal, centrifugal, multi -stage, double -string, sectional type, with a radial connector of the case. The design of the pumps fully complies with the requirements of the ISO 13709 standard (API 610), type BB5.
No. |
Pump brand |
feed, m 3 Sup>/h |
pressure, m |
Frequency of rotation, rpm (synchr.) |
engine power, kW TR> |
---|---|---|---|---|---|
1 |
TsNSDP 45-700 |
45 |
700 |
3000 |
315 |
TR>
2 |
TsNSDP 45-900 |
45 |
900 |
3000 |
315 |
TR>
3 |
Central Military District 45-1050 |
45 |
1050 |
3000 |
500 |
TR>
4 |
TsNSDP 45-1150 |
45 |
1150 |
3000 |
500 |
TR>
5 |
TsNSDP 45-1275 |
45 |
1275 |
3000 |
500 |
TR>
6 |
TsNSDP 45-1422 |
45 |
1422 |
3000 |
630 |
TR>
7 |
TsNSDP 45-1525 |
45 |
1525 |
3000 |
630 |
TR>
8 |
Central Military District 45-1650 |
45 |
1650 |
3000 |
630 |
TR>
9 |
TsNSDP 45-1775 |
45 |
1775 |
3000 |
800 |
TR>
10 |
TsNSDP 45-1900 |
45 |
1900 |
3000 |
800 |
TR>
11 |
TsNSDP 45-2100 |
45 |
2100 |
3000 |
800 |
TR>
12 |
TsNSDP 63-700 |
63 |
700 |
3000 |
500 |
TR>
13 |
TsNSDP 63-900 |
63 |
900 |
3000 |
500 |
TR>
14 |
TsNSDP 63-1050 |
63 |
1050 |
3000 |
500 |
TR>
15 |
TsNSDP 63-1150 |
63 |
1150 |
3000 |
500 |
TR>
16 |
TsNSDP 63-1275 |
63 |
1275 |
3000 |
630 |
TR>
17 |
Central Military District 63-1422 |
63 |
1422 |
3000 |
630 |
TR>
18 |
TsNSDP 63-1525 |
63 |
1525 |
3000 |
630 |
TR>
19 |
TsNSDP 63-1650 |
63 |
1650 |
3000 |
800 |
TR>
20 |
TsNSDP 63-1775 |
63 |
1775 |
3000 |
1000 |
TR>
21 |
TsNSDP 63-1900 |
63 |
1900 |
3000 |
1000 |
TR>
22 |
TsNSDP 63-2100 |
63 |
2100 |
3000 |
800 |
TR>
23 |
Central Military District 90-700 |
90 |
700 |
3000 |
500 |
TR>
24 |
TsNSDP 90-900 |
90 |
900 |
3000 |
500 |
TR>
25 |
Central Military District 90-1050 |
90 |
1050 |
3000 |
630 |
TR>
26 |
Central Military District 90-1150 |
90 |
1150 |
3000 |
630 |
TR>
27 |
Central Military District 90-1275 |
90 |
1275 |
3000 |
630 |
TR>
28 |
Central Military District 90-1422 |
90 |
1422 |
3000 |
800 |
TR>
29 |
Central Military District 90-1525 |
90 |
1525 |
3000 |
800 |
TR>
30 |
Central Military District 90-1650 |
90 |
1650 |
3000 |
800 |
TR>
31 |
TsNSDP 90-1775 |
90 |
1775 |
3000 |
1000 |
TR>
32 |
Central Military District 90-1900 |
90 |
1900 |
3000 |
1000 |
TR>
33 |
Central Human Resurrection 90-2100 |
90 |
2100 |
3000 |
1000 |
TR>
34 |
Central Military District 120-750 |
120 |
700 |
3000 |
800 |
TR>
35 |
TsNSDP 120-900 |
120 |
900 |
3000 |
1000 |
TR>
36 |
Central Military District 120-1050 |
120 |
1050 |
3000 |
1000 |
TR>
37 |
Central Military District 120-1150 |
120 |
1150 |
3000 |
1000 |
TR>
38 |
TsNSDP 120-1275 |
120 |
1275 |
3000 |
1000 |
TR>
39 |
TsNSDP 120-1422 |
120 |
1422 |
3000 |
1250 |
TR>
40 |
Central Military District 120-1525 |
120 |
1525 |
3000 |
1250 |
TR>
41 |
Central Military District 120-1650 |
120 |
1650 |
3000 |
1600 |
TR>
42 |
TsNSDP 120-1775 |
120 |
1775 |
3000 |
1600 |
TR>
43 |
TsNSDP 120-1900 |
120 |
1900 |
3000 |
1600 |
TR>
44 |
Central Military District 120-2100 |
120 |
2100 |
3000 |
1250 |
TR>
45 |
TsNSDP 180-700 |
180 |
700 |
3000 |
800 |
TR>
46 |
TsNSDP 180-900 |
180 |
900 |
3000 |
800 |
TR>
47 |
Central Military District 180-1050 |
180 |
1050 |
3000 |
100 |
TR>
48 |
TsNSDP 180-1150 |
180 |
1150 |
3000 |
1000 |
TR>
49 |
TsNSDP 180-1275 |
180 |
1275 |
ZOOO |
1000 |
TR>
50 |
TsNSDP 180-1422 |
180 |
1422 |
3000 |
1250 |
TR>
51 |
TsNSDP 180-1525 |
180 |
1525 |
3000 |
1250 |
TR>
52 |
TsNSDP 180-1650 |
180 |
1650 |
3000 |
1600 |
TR>
53 |
TsNSDP 180-1775 |
180 |
1775 |
3000 |
1600 |
TR>
54 |
TsNSDP 180-1900 |
180 |
1900 |
3000 |
1600 |
TR>
55 |
Central Military District 180-2100 |
180 |
|