Technical characteristics of the ABDM-100 units ... 630
No.
|
name of the parameter and size
|
value for the unit |
TR>
||||
AVDM- 100 |
AVDM- 160 |
AVDM- 250 |
AVDM- 400 |
AVDM- 630 |
TR>
||
1. |
The speed of action in the range of working pressure from 6.6 · 10-4 to 1.3 · 10-1 PA (from 5 · 10-6 to 1 · 10-3 mm Hg), l/s* p > |
130 ± 10 |
310 ± 25 |
870 ± 90 |
2280 ± 250 |
5750 ± 500 |
TR>
2. |
Maximum residual pressure, PA (mm RT. Art.), No more at the temperature of the surrounding air: from plus 10 to minus 25ºC inclusive St. Plus 25 to minus 45ºC |
6.6 · 10-5 (5 · 10-7) 6.6 · 10-4 (5 · 10-6) |
TR>
||||
3. |
The largest exhaust pressure, PA (mm Hg art.) No less* |
35 (0.263) |
33.3 (0.25) |
33.3 (0.25) |
33.3 (0.25) |
33.3 (0.25) |
TR>
4. |
Power consumption at rated voltage, W, Including, the power of the pump heater at rated voltage: 220 in
380 V |
563+30 -10
500+30 -10
|
900+40 -80
800+40 -80 |
2100+90 -30
2000+90 -30 |
4200+90 -30
4000+90 -30 |
9500+450 -900
9000+450 -900 |
TR>
5. |
Conditional passage, mm, at the entrance |
100 |
160 |
250 |
400 |
630 |
TR>
6. |
Dimensional dimensions, mm, no more than* Height Length Width |
670 630 450 |
750 720 540 |
1150 840 780 |
1440 1350 930 |
2100 1900 1400 |
TR>
7. |
Mass, kg, no more than* |
40 |
65 |
140 |
294 |
870 |
TR>