conventions h2>
Irtysh-TSMK1 32/125-1.5/2
Irtysh - a series of pumps
CMK - centrifugal monoblock console pump
1 - option of cutting the working wheel
32 - conditional passage of the pressure pipe
125 - nominal diameter of the working wheel
1.5 - nominal power of the electric motor
Application < /span> span> h2>
water supply, supply of cold and hot water without abrasive substances in heating systems, cold and cooling water installations, as well as for irrigation and fire extinguishing installations.
When using additives, such as glycol or oil, you should check the suitability of the seal and the need to change power (when the glycol is added from 10% of the volumetric part).
Technical data h2>
Permissible pumped media :
Water of heating systems
Technical. Water - cooling./Cold water
Water glycol mixes
characteristics: < /Strong>
-
number 100, 1500, 1500 3000 rpm
-
Defense degree-IP 44 < /span>
-
climatic execution- span>
-
Postics category-3 span>
-
nominal diameter DY 32-150
-
temperature range from -10 < Span Style = "Position: Relative; Line-Height: 0; Vertical-aligne: Baseline; Top: -0.5em; Bottom: 0.3em;"> 0 C to +110 ° C (indicate the pr request) < /span>
-
The maximum pressure at the input of 6 kgs/ cm²
-
The maximum permissible environmental temperature + 40 ° with
Electrical separation Strong> 3-380 V, 50 Hz
Motor protection is required additionally (on request)
motor winding isolation class f
System for regulating the number of revolutions by order
Specialization engine Explosion protection by order
Materials < /span> span> h2>
The body is a pumped cast iron < Br/>
Working wheel-gray cast iron
Val-steel 45
Thin seal - graphite/silicon carbide
design Strong>
Single -stage circulation pump of low pressure, compact design, for modern buildings equipment.
the pump case < /Strong>
A spiral cast -iron case with an axial absorption, radial pressure pipes and with cast legs for installation on the foundation.
ANSTRUCTIONAL FLANTS RU = 16 kgs/cm² according to GOST 12820-80.
When using additives, such as glycol or oil, you should check the suitability of the seal and the need to change power (when the glycol is added from 10% of the volumetric part).
Water of heating systems
Technical. Water - cooling./Cold water
Water glycol mixes
Motor protection is required additionally (on request)
motor winding isolation class f
System for regulating the number of revolutions by order
Specialization engine Explosion protection by order
The body is a pumped cast iron < Br/>
Working wheel-gray cast iron
Val-steel 45
Thin seal - graphite/silicon carbide
design Strong>
Single -stage circulation pump of low pressure, compact design, for modern buildings equipment.
the pump case < /Strong>
A spiral cast -iron case with an axial absorption, radial pressure pipes and with cast legs for installation on the foundation.
ANSTRUCTIONAL FLANTS RU = 16 kgs/cm² according to GOST 12820-80.