Screwline Forvacuum pumps of dry compression , The principle of operation is based on rotation Randies . In addition to the integrated rotor cooling system, standard versions of the pumps are equipped with air cooling from the outside. The compression cavity of the vacuum pump is formed by two synchronously rotating rotors and the surface of the housing. Due to the rotation of the rotors in opposite directions, the compression cavity is gradually moving from the absorption side to the exhaust side, thus carrying out the pumping process. P>
Fields of application:
- Industrial furnaces
- Technology for applying coatings
- Metallurgical Systems s
- Packaging technology
- drying processes
- degassing
- Scientific research and development
- Automotive industry
- Packaging industry
- Modeling Space conditions
- Electrical Engineering SPAN>
- Studies in the field of energy
"> "> Screwline SP 250 h1>
Name of the parameter |
Meaning |
TR>
1 entrance flange |
ISO 1609-1986 (E) –63 (DN 63 ISO -K) Asme B 16.5 NPS 3 Class 150 EN 1092-2 - PN 6 - Dn 65
|
TR>
2 output flanet |
ISO 1609-1986 (E) –63 (DN 63 ISO -K)
|
TR>
3 speed of action at a frequency of 50 Hz, m 3 Sup>/h |
270.0 |
TR>
4 speed of action at a frequency of 60 Hz, m 3 Sup>/h |
330.0 |
TR>
5 maximum residual pressure without gas, MBAR (mm Hg) - at a frequency of 50 Hz - at a frequency of 60 Hz |
1.0x10 -2 Sup> (7.5x10 -3 Sup>) 5.0x10 -3 Sup> (3.8x10 -3 Sup>) |
TR>
6 maximum residual pressure with gas -ballast, MBAR (mm Hg) - at a frequency of 50 Hz - at a frequency of 60 Hz |
2.0x10 -1 Sup> (1.5x10 -1 Sup>) 2.0x10 -2 (1.5x10 -2 Sup>) |
TR>
7 acceptable pressure of water vapor at a frequency of 50 Hz, MBAR |
60.0 |
TR>
8 Permissible pressure of water vapor at a frequency of 60 Hz, MBAR |
75.0 |
TR>
9 Water Paragraph performance at a frequency of 50 Hz, kg/h |
10.0 |
TR>
10 Water Paragraph performance at a frequency of 60 Hz, kg/h |
18.0 |
TR>
11 Number of working fluid, l |
7.0 |
TR>
12 noise level with gas -ballast, dB - 50 Hz - 60 Hz |
67 72 |
TR>
13 ELECTION EL/DOWN. From a network of three -phase alternating current with a frequency of 50/60 Hz, voltage, in |
200, 380-400-415 200-220-230, 460
|
TR>
14 Electric motor power at a frequency of 50 Hz, kW |
7.5 |
TR>
15 Electric motor power at a frequency of 60 Hz, kW |
11.5 |
TR>
16 angular velocity at a frequency of 50 Hz, rpm |
2910 |
TR>
17 angular speed at a frequency of 60 Hz, rpm |
3490 |
TR>
18 degree of protection of the electric motor |
IP 55 |
TR>
19 acceptable ambient temperature, o sup> s |
+5 to +40 |
TR>
20 mass, kg |
450.0 |
TR>
Name of the parameter |
Meaning |
TR>
1 entrance flange/ output flange |
EN 1092-2 - PN 6 - Dn 100 EN 1092-2-PN 16 - DN 100 ISO 1609-1986 (E) –100 (DN 100 ISO -K) Asme B 16.5 NPS4 Class 150
|
TR>
3 speed of action at a frequency of 50 Hz, m 3 Sup>/h |
630.0 |
TR>
4 speed of action at a frequency of 60 Hz, m 3 Sup>/h |
630.0 |
TR>
5 maximum residual pressure without gas, MBAR (mm Hg) - at a frequency of 50 Hz - at a frequency of 60 Hz |
1.0x10 -2 Sup> (7.5x10 -3 Sup>) 1.0x10 -2 Sup> (7.5x10 -3 Sup>) |
TR>
6 maximum residual pressure with gas -ballast, MBAR (mm Hg) - at a frequency of 50 Hz - at a frequency of 60 Hz |
1.0x10 -1 Sup> (7.5x10 -2 Sup>) 1.0x10 -1 Sup> (7.5x10 -2 Sup>) |
TR>
7 acceptable pressure of water vapor at a frequency of 50 Hz, MBAR |
40.0 |
TR>
8 Permissible pressure of water vapor at a frequency of 60 Hz, MBAR |
45.0 |
TR>
9 Water Paragraph performance at a frequency of 50 Hz, kg/h |
14.0 |
TR>
10 Water Paragraph performance at a frequency of 60 Hz, kg/h |
14.0 |
TR>
11 Number of working fluid, l |
15.0 |
TR>
12 noise level with gas -ballast, dB - 50 Hz - 60 Hz |
73 75 |
TR>
13 ELECTION EL/DOWN. From a network of three -phase alternating current with a frequency of 50 Hz, voltage, in |
200/400
|
TR>
14 Electric motor power at a frequency of 50 Hz, kW |
15.0 |
TR>
15 Electric motor power at a frequency of 60 Hz, kW |
15.0 |
TR>
16 angular velocity at a frequency of 50 Hz, rpm |
2930 |
TR>
17 angular speed at a frequency of 60 Hz, rpm |
3530 |
TR>
18 degree of protection of the electric motor |
IP 55 |
TR>
19 acceptable ambient temperature, o sup> s |
+5 to +40 |
TR>
20 mass, kg |
530.0 |
TR>