Electric pump unit is designed to pump water, petroleum products and raw oil with kinematic viscosity of up to 300 sons (300 × 10-6 m2/c) and a temperature of minus 10 ° C to plus 80º C.S. Aggregate It is made in execution for installation in explosive and fire hazardous areas in which the class of premises B-IA and lower in accordance with the PUE (the rules for the installation of electrical installations) for pumping liquids, the pairs of which form explosive mixtures with air of category II and IIV
According to GOST R 51330.11-99 and groups T1, T2, T3, T4 according to GOST R 51330.5-99.
Depending on the density and viscosity of the pumped fluid and the requirements of the explosion - fire hazard, the pumps are equipped with different power and execution by engines, including the diesel engine
NK 100/215 | NK 200/108 | TR>|
type td> | "> centrifugal, two -way | TR>|
the number of steps td> | "> 4 td> TR> | |
The presentation is nominal, M 3 Sup>/h | 100 td> | 200 td> TR> |
The pressure with a nominal feed, m | 215 td> | 108 td> TR> |
The rotor speed is nominal (given), about/min | "> 2900 td> TR> | |
The maximum pump power consumption in the entire working range of feeds, at the speed of the pump shaft 2900 q. Min when working on water, kW, no more than |
"> 105 td> TR> | |
The maximum excess pressure at the pump input, MPa TD> | "> 3.1 td> TR> | |
permissible cavitation reserve (with a nomanal speed of rotation), m, no more than | "> 5.5 td> TR> | |
leaks through the end seals, l/hour, no more than | "> 0.05 td> TR> | |
the mass of the pump, kg, no more than | "> 840 td> TR> |