Sectional centrifugal pumps (hereinafter referred to as the pump) type 500 are designed for pumping water with a temperature of up to 45 ° C, with the content of solid mechanical impurities of not more than 0.1 % in weight, with the size of solid particles of not more than 0.1 mm, microcharles not more than 1, 47 GPA. The maximum permissible pressure at the entrance to the pump is not more than 0.25 MPa (2.5 kgf/cm2).
The pump should be made in the climatic design of the UHL, the placement category 4 GOST 15150-69.
Pump central NSS 500-120 has a designation:
Central nervous system - centrifugal section of sectional;
500 - nominal feed in m3/h;
120 - pressure in m.
Characterization of the pump centerial pump 500
Pump description
The working part of the characteristics at a rotation frequency of 1475 rpm is located in the feed interval 225 ... 375 m3/h.
The main parameters of the pump corresponding to the nominal mode of operation on water with a temperature of 20 ° C and a density of 998.2 kgf/m3
Permissible maximum pressure deviations from +5 % to minus 5 %;
The permissible pressure reduction during operation by 10 % of the value indicated in the table;
The power is indicated in the nominal mode.
Mark | Feed, m3/h | Ples, m | Rotation frequency, rpm |
Power, Trus-I pump, kW | PPD pump, %, no less |
Permissible cavitation reserve, m, no more TR> |
---|---|---|---|---|---|---|
Central nervous system 500-160 | 500 | 160 | 1475 | 307 | 71 | 5 | TR>
Central nervous system 500-240 | 240 | 461 | TR>||||
Central nervous system 500-320 | 320 | 614 | TR>||||
Central nervous system 500-400 | 400 | 767 | TR>||||
Central nervous system 500-480 | 480 | 921 | TR>||||
Central nervous system 500-560 | 560 | 1074 | TR>||||
Central nervous system 500-640 | 640 | 1228 | TR>||||
Central nervous system 500-720 | 720 | 1381 | TR>||||
Central nervous system 500-800 | 800 | 1534 | TR>||||
Central nervous system 500-880 | 880 | 1688 | TR>||||
Central nervous system 500-1000* | 1000 | 1960 | TR>